Abstract

This study aims to determine the effect of the time-based maintenance method preventive maintenance, namely major inspection on the efficiency of H-25 gas turbine. The efficiency calculation method based on operating data from the gas turbine. The effect of major inspection can be seen from the compressor efficiency, turbine efficiency and fuel consumption. The results of calculations before the major inspection are 80% of compressor efficiency, 83% of turbine efficiency, and 0.751 kg/kWh of fuel consumption, while after the major inspection, compressor efficiency is 80%, turbine efficiency is 85% and fuel consumption is 0.740 kg/kWh.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.