Abstract

Anastomotic complications, including leaks, stenoses, and bleeding, cause considerable mortality and morbidity after colorectal surgery. The purpose of this work was to evaluate the effectiveness of bioabsorbable staple line reinforcement in reducing colorectal anastomotic complications. This was a prospective randomized clinical study. This study was conducted at a university hospital within a specialized colorectal unit. Patients undergoing left colon resection for a benign or malignant condition were eligible. A total of 302 patients participated, including 154 control subjects and 148 with reinforcement. Patients were prospectively randomly assigned to reinforcement of circular stapled anastomosis with a bioabsorbable device versus stapled circular anastomosis without reinforcement. The primary end point was the rate of pooled incidences of anastomotic complications (leakage, bleeding, or stenosis). Secondary outcomes were the rate of reoperations and the length of hospital stay. Baseline characteristics were similar between both groups. Intention-to-treat analysis revealed that there were no significant differences in the pooled incidences of anastomotic complications (p = 0.821). Regarding individual complications, we did not observe statistical differences between groups, including leakage (6.6% vs 4.8%; p = 0.518), hemorrhage (1.4% vs 1.3%; p = 0.431), or stenosis (2.9% vs 6.8%; p = 0.128). Again, no significant differences were observed in length of stay (7 days; p = 0.242) or rate of reoperation (7.3% vs 9.6%; p = 0.490). A patient (0.3%) in the control group died. Sample size calculation was performed including all 3 of the complications, which may render it underpowered to detect differences regarding a specific complication. Anastomoses located within 5 cm from the anal verge were excluded from the study. The results obtained show that bioabsorbable staple line reinforcement in a colorectal anastomosis >5 cm from the anal verge does not reduce the rate of pooled anastomotic complications (ie, leaks, bleeding, or stenosis).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.