Abstract

Arteriovenous malformations (AVMs) are composed of abnormal arterial and venous vessels in the brain causing arteriovenous shunts of arterialized blood directly from pial arteries to draining veins. The hemodynamics of these lesions is not well-understood. Changes in blood flow and pressure are probably related to the natural history of AVMs and may also play a major role in AVM treatment. In this study intra-arterial pressure was measured in feeding arteries of AVMs using a microcatheter that had been placed for subsequent embolization treatment (201 measurements were performed in 95 patients before and after the embolization procedure). Results show a direct relationship between pressure changes and degree of embolization. Since pressure changes during the embolization procedure are relatively small, it seems unlikely that these changes are the direct cause of rupture and periprocedural bleedings.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.