Abstract

Experiments have been performed on the pressure drop of a spacer grid in rod bundles of 12 rods. Both smooth and rough rod bundles were used in the experiments. The artificial roughness cut into the outer surface of the rods was chosen so as to meet the actual design of a gas-cooled fast breeder reactor. The results of this investigation for a Reynolds number range between Re = 4 x 10/sup 3/ and 7 x 10/sup 4/ indicate that the pressure drop at the spacer grids is higher in a roughened rod bundle than in a smooth rod bundle.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.