Abstract
The failure of the secondary side in Gas Cooled Fast Reactor system, which may contain co-generation system, will cause loss of heat sink (LOHS) accident. In this study accident analysis of unprotected loss of heat sink due to the failure of the secondary cooling system has been investigated. The thermal hydraulic model include transient hot spot channel model in the core, steam generator, and related systems. Natural circulation based heat removal system is important to ensure inherent safety capability during unprotected accidents. Therefore the system similar to RVACS (reactor vessel auxiliary cooling system) is also plays important role to limit the level of consequence during the accident. As the results some simulations for small 60 MWt gas cooled fast reactors has been performed and the results show that the reactor can anticipate the failure of the secondary system by reducing power through reactivity feedback and remove the rest of heat through natural circulations based decay heat removal (RVACS system).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.