Abstract
Although there are many reasons for extubation failure, maintaining negative or lower positive fluid balances 24 hours before extubation may be a key measure for successful extubation. To assess the predictive value of fluid balance before extubation and its outcome in mechanically ventilated cases in the intensive care unit (ICU). This retrospective cohort study involved collecting clinical data from patients undergoing mechanical ventilation in Lanzhou general adult ICU from January 2022 to December 2022. Based on extubation outcomes, the patients were divided into a successful extubation group and a failed extubation group. Their fluid balance levels 24 h before extubation were compared with analyse the predictive value of fluid balance on extubation outcomes in patients undergoing mechanical ventilation. In this study, clinical data from 545 patients admitted to a general adult ICU were collected. According to the inclusion and exclusion criteria, 265 (48.6%) patients were included, of which 197 (74.3%) were successfully extubated; extubation was unsuccessful in 68 (25.7%) patients. The total intake and fluid balance levels in patients in the failed extubation group 24 h before extubation were significantly higher than those in the successful extubation group, with a median of 2679.00 (2410.44-3193.50) mL versus 2435.40 (1805.04-2957.00) mL, 831.50 (26.25-1407.94) mL versus 346.00 (-163.00-941.50) mL. Receiver operating characteristic (ROC) curve analysis showed that the optimal cut-off value for predicting extubation outcomes was 497.5 mL (sensitivity 64.7%, specificity 59.4%) for fluid balance 24 h before extubation. The area under the ROC curve was 0.627 (95% confidence interval [CI] 0.547-0.707). Based on the logistic regression model, cumulative fluid balance >497.5 mL 24 h before extubation could predict its outcomes in mechanically ventilated patients in the ICU (OR = 5.591, 95% CI [2.402-13.015], p < .05). The fluid balance level 24 h before extubation was correlated with the outcome of extubation in mechanically ventilated patients in the ICU. The risk of extubation failure was higher when the fluid balance level was >497.5 mL. Tracheal intubation is a crucial life support technique for many critically ill patients, and determining the appropriate time for extubation remains a challenge for clinicians. Although there are many reasons for extubation failure, acute pulmonary oedema caused by continuous positive fluid balance and volume overload is one of the main reasons for extubation failure. Therefore, it is very important to study the relationship between fluid balance and extubation outcome to improve the prognosis of patients with invasive mechanical ventilation in ICU.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.