ObjectivesA screening model for prediction of small-for-gestational-age (SGA) neonates (SGAp) was established by logistic regression using ultrasound data and maternal factors (MF). We aimed to evaluate the ability of SGAp as well as abdominal circumference (AC) and estimated fetal weight (EFW) measurements to predict SGA neonates at 33–39 weeks’ gestation.MethodsThis retrospective study evaluated 5298 singleton pregnancies that had involved three ultrasound examinations at 21+0–27+6, 28+0–32+6, and 33+0–39+6 weeks. All ultrasound data were transformed to MoM values (multiple of the median). Multivariate logistic regression was used to analyze the correlation between SGA status and various variables (ultrasound data and MF) during pregnancy to build the SGAp model. EFW was calculated according to the Hadlock formula at 33–39 weeks of gestation. The predictive performance of SGAp, AC MoM value at 33+0–39+6 weeks (AC-M), EFW MoM value (EFW-M), EFW-M plus MF, AC value at 33+0–39+6 weeks (AC), AC growth velocity, EFW, and EFW plus MF was evaluated using ROC curves. The detection rate (DR) of SGA neonate with SGAp, AC-M, EFW-M, and EFW-M plus MF at false positive rate (FPR) of 5% and 10%, and the FPR at DR of 85%, 90%, and 95% were observed.ResultsThe AUCs of SGAp, AC-M, EFW-M, EFW-M plus MF, AC, AC growth velocity, EFW, and EFW plus MF for SGA neonates screening were 0.933 (95%CI: 0.916–0.950), 0.906 (95%CI: 0.887–0.925), 0.920 (95%CI: 0.903–0.936), 0.925 (95%CI: 0.909–0.941), 0.818 (95%CI: 0.791–0.845), 0.786 (95%CI: 0.752–0.821), 0.810 (95%CI: 0.782–0.838), and 0.834 (95%CI: 0.807–0.860), respectively. The screening efficiency of SGAp, AC-M, EFW-M, and EFW-M plus MF are significantly higher than AC, AC growth velocity, EFW, and EFW plus MF. The DR of SGAp, AC-M, EFW-M, and EFW-M plus MF for SGA neonates were 80.4%, 69.6%, 73.8% and 74.3% at 10% FPR. The AUCs of SGAp, AC-M, EFW-M, and EFW-M plus MF 0.950 (95%CI: 0.932–0.967), 0.929 (95%CI: 0.909–0.948), 0.938 (95%CI: 0.921–0.956) and 0.941 (95%CI: 0.924–0.957), respectively for screening SGA neonates delivered within 2 weeks after the assessment. The DR for these births increased to 85.8%, 75.8%, 80.0%, and 82.5%, respectively.ConclusionThe rational use of ultrasound data can significantly improve the prediction of SGA statuses.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.