Abstract

The microelectronics industry is pushing the fundamental limit on the physical size of individual elements to produce faster and more powerful integrated chips. These chips have nanoscale features that dissipate power resulting in nanoscale hotspots leading to device failures. To understand the reliability impact of the hotspots, the device needs to be tested under the actual operating conditions. Therefore, the development of high-resolution thermometry techniques is required to understand the heat dissipation processes during the device operation. Recently, several thermometry techniques have been proposed, such as radiation thermometry, thermocouple based contact thermometry, scanning thermal microscopy, scanning transmission electron microscopy and transition based threshold thermometers. However, most of these techniques have limitations including the need for extensive calibration, perturbation of the actual device temperature, low throughput, and the use of ultra-high vacuum. Here, we present a facile technique, which uses a thin film contact thermometer based on the phase change material Ge_2 Sb_2 Te_5, to precisely map thermal contours from the nanoscale to the microscale. Ge_2 Sb_2 Te_5 undergoes a crystalline transition at hbox {T}_{{g}} with large changes in its electric conductivity, optical reflectivity and density. Using this approach, we map the surface temperature of a nanowire and an embedded micro-heater on the same chip where the scales of the temperature contours differ by three orders of magnitude. The spatial resolution can be as high as 20 nanometers thanks to the continuous nature of the thin film.

Highlights

  • The microelectronics industry is pushing the fundamental limit on the physical size of individual elements to produce faster and more powerful integrated chips

  • A novel technique, which uses a phase change material to map the temperature of an operational microelectronic device, is presented

  • It is quantitatively demonstrated that the temperature measured from the phase change temperature contour (PCTC) technique agrees well with the measured average surface temperature and the thermal simulation for both the micro-heater and the nano-heater

Read more

Summary

Introduction

The microelectronics industry is pushing the fundamental limit on the physical size of individual elements to produce faster and more powerful integrated chips. Ge2Sb2Te5 undergoes a crystalline transition at Tg with large changes in its electric conductivity, optical reflectivity and density Using this approach, we map the surface temperature of a nanowire and an embedded micro-heater on the same chip where the scales of the temperature contours differ by three orders of magnitude. A novel technique, which uses a phase change material to map the temperature of an operational microelectronic device, is presented It requires minimal effort in temperature calibration and the temperature contour can be mapped using both contact and non-contact modes such as AFM, SEM or optical ­microscopes[28,29,30,31,32]. It is quantitatively demonstrated that the temperature measured from the phase change temperature contour (PCTC) technique agrees well with the measured average surface temperature and the thermal simulation for both the micro-heater and the nano-heater

Methods
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.