Abstract

The use of an ultra low expansion cavity plays a crucial role in laser stabilization, and it is essential in atomic or ion clocks. In this work we present a method of mirror distance monitoring in an evacuated Fabry-Perot cavity (FPC) made from an ultra low expansion material (Zerodur expansion class 0). The FPC was placed into a temperature-stabilized stainless steel chamber and the FPC temperature was set to remain close to the point where the expansion coefficient of the cavity material is the lowest. The precise distance of the FPC mirrors in vacuum was indirectly proportional to the optical frequency of a laser. One of the frequency comb component chosen by FBG grating was locked to the FPC of 400 MHz free spectral range. The 100 MHz repetition frequency of the femtosecond laser comb was monitored with counter referenced to a crystal oscillator with short term stability <; 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-12</sup> and long term stability locked to a GPS.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.