Abstract

Aim:We investigated the effect of pre-analytical sample handling variations on coronavirus disease 2019-relevant circulating cytokine levels IFN-γ, IL-10, IL-12p70, IL-17A, IL-6 and TNF-α.Materials & methods:We collected blood in different collection tubes (ethylenediaminetetraacetic acid, sodium citrate, lithium heparin, serum), and subjected ethylenediaminetetraacetic acid plasma to among others increasing delays in centrifugation or -80°C storage. Six subjects were included in each experimental condition. Cytokine levels were measured in these samples using the Simoa Cytokine 6-plex kit.Results:Different tube types resulted in different blood cytokine levels. IL-17A and IL-6 levels declined with 3 h centrifugation delay. IFN-γ levels declined with 24 h postcentrifugation storage delay. IL-17A levels declined with 2-week storage delay.Conclusion:It is recommended to centrifuge tubes quickly following collection, for accurate cytokine measurement.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.