Abstract

The development of new biopharmaceuticals relies on robust scale-up from small-scale screening studies to industrial bioreactors. Novel SUB designs can prove highly beneficial, although they lack the extensive characterisation of traditional STRs. Pall Corporation’s Allegro™ STR 50–2000 L bioreactor range has a unique design of square cross-section, with three wedge-shaped baffles. A scale-down 1 L prototype (abbreviated A-STR) was developed for characterisation studies and compared to a standard cylindrical STR (abbreviated S-STR). Agreement of power and mixing number data with that of the Allegro STR 200 L indicated successful scale-down. In down-pumping mode, mixing times in the A-STR were approximately 53 % lower than in the S-STR. However, in up-pumping mode both configurations exhibited similar mixing times. This study utilises a scale-down prototype to provide quantitative data on the commercial Allegro STR bioreactor range, to define operating parameters for enhanced scalability, and for comparison with a standard bioreactor geometry.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.