Abstract

In the present paper, CFD simulation is used to perform the numerical calculation of behaviours of multi-blade drag typed VAWT. The sliding grid technology, FLUENT software and PISO algorithm are involved. By taking wind power efficiency Cp as the goal function, the optimal situations of multi-blade drag typed VAWT with 4 and 6 blades are conducted by CFD simulation. In this investigation, the variable parameters include the rotation rate of wind-mill ω, the blade installation angle θ and the blade width d. The results show that: the optimal working conditions for the 4-blade wind mill at the inlet wind speed 8 m/s are ω = 18 r/ min, θ = 28°, and d = 0.83 m, which induces an optimal wind power efficiency rate Cp = 27.127%; the optimal working conditions for the 6-blade wind mill at the inlet wind speed 8 m/s are ω = 18 r/min, θ = 27°, and d = 0.67 m, which leads to an optimal wind power efficiency rate Cp = 30.404%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.