Abstract

We sought to evaluate radioisotope cisternography (RICG)-related postpuncture CSF leakage by MRI. We conducted a prospective 3-day imaging study. Ten patients with orthostatic headache and other symptoms underwent pre-RICG brain and spinal MRI, magnetic resonance myelography (MRM), RICG, and post-RICG spinal MRI and MRM. For RICG, we used a 25-gauge pencil point spinal needle at the L3/4 or L4/5 level after which subjects took bed rest for 2.5 hours. On pre-RICG MRI and MRM, none of the 10 patients showed CSF leakage. However, 5 subjects (50%) showed epidural abnormalities suggesting CSF leakage on MRI after lumbar puncture for RICG. On RICG and subsequent MRM, 4 of the subjects showed definite findings of CSF leakage and 1 showed minimal leakage. RICG carries a risk of iatrogenic CSF leakage even with careful puncturing using a fine needle. This leakage produces abnormal RICG and MRM findings at the lumbosacral level. Therefore, abnormal RICG findings restricted to the lumbosacral level should be carefully interpreted when diagnosing SIH.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.