Abstract

ObjectiveTo identify the wideband absorbance (WBA) of reconstructed TM comparing with perforated and normal TM, and to investigate the efficacy of WBA to predict postoperative hearing outcome. MethodsNinety-eight adults (128 ears) with normal TM and 40 patients (40 ears) who were diagnosed with chronic suppurative otitis media (CSOM) and underwent tympanoplasty type 1 were enrolled. Pure tone audiometry and WBA were measured before and 6 and 12 months after surgery. Finally, only 29 patients in CSOM group completed all the tests. ResultsSignificant differences in WBA were observed between normal ears, CSOM, and reconstructed ears at middle to high frequencies. During follow-up, absorbance decreased at low frequencies and increased at middle to high. Significant positive correlation at low to middle frequency was observed between change in air-bone gaps (ABG) and absorbance at corresponding frequencies. ConclusionWBA in patients with CSOM was significantly different from normal TM, and a significant change in WBA was observed after tympanoplasty with improvement of ABG. WBA may be a useful tool for monitoring the postoperative change in absorbance of sound energy in the middle ear.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.