Processing of ultrasonic array data is traditionally based on having parallel transmission circuits that enable staggered firing of transmitter elements to produce the desired wavefront. This paper describes an alternative approach in which the full matrix of time domain signals from every transmitter–receiver pair is captured and post-processed. Various post-processing approaches are modelled and assessed in terms of their ability to image a point-like reflector. Experimental results are then presented which show good quantitative agreement with the modelled results. An advanced processing algorithm is also implemented which allows the array to be focused at every point in the target region in both transmission and reception. This approach is shown to offer significant performance advantages for NDE.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.