Abstract
Experimental and analytical results are presented for the post-failure behavior of quasi-isotropic glass-epoxy laminates with a central circular hole. Load-strain response is predicted by combining a failure model developed from tests of unnotched laminates with a tangent-modulus finite-element analysis of the notched laminate. The prediction is shown to agree both qualitatively and quantitatively with experimental results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.