Abstract

This paper presents an approach for self-sensing piezoelectric valves. Both displacement and actuation force of piezoelectric valve can be simultaneously estimated from measurements of the charge and driving voltage. Only simple calibration is required before engineering application. The charge is obtained by software integration of the piezoelectric current sampled by DAQ card, which has the advantage of compensating leakage current by pre-estimating the leakage resistance. A PID controller is used to track the displacement, and a feedfoward compensation using Prandtl–Ishlinskii model is taken to compensate the piezoelectric hysteresis. The experimental results show that the controller can track target displacement within 2.03% of error, track force within 1.80% of error, and the maximum hysteresis of actuator is compensated from 27% to 3.75%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.