Abstract

The relationship between the diaphragm thickening fraction and the transdiaphragmatic pressure, the reference method to evaluate the diaphragm function, has not been clearly established. This study investigated the global and intraindividual relationship between the thickening fraction of the diaphragm and the transdiaphragmatic pressure. The authors hypothesized that the diaphragm thickening fraction would be positively and significantly correlated to the transdiaphragmatic pressure, in both healthy participants and ventilated patients. Fourteen healthy individuals and 25 mechanically ventilated patients (enrolled in two previous physiologic investigations) participated in the current study. The zone of apposition of the right hemidiaphragm was imaged simultaneously to transdiaphragmatic pressure recording within different breathing conditions, i.e., external inspiratory threshold loading in healthy individuals and various pressure support settings in patients. A blinded offline breath-by-breath analysis synchronously computed the changes in transdiaphragmatic pressure, the diaphragm pressure-time product, and diaphragm thickening fraction. Global and intraindividual relationships between variables were assessed. In healthy subjects, both changes in transdiaphragmatic pressure and diaphragm pressure-time product were moderately correlated to diaphragm thickening fraction (repeated measures correlation = 0.40, P < 0.0001; and repeated measures correlation = 0.38, P < 0.0001, respectively). In mechanically ventilated patients, changes in transdiaphragmatic pressure and thickening fraction were weakly correlated (repeated measures correlation = 0.11, P = 0.008), while diaphragm pressure-time product and thickening fraction were not (repeated measures correlation = 0.04, P = 0.396). Individually, changes in transdiaphragmatic pressure and thickening fraction were significantly correlated in 8 of 14 healthy subjects (ρ = 0.30 to 0.85, all P < 0.05) and in 2 of 25 mechanically ventilated patients (ρ = 0.47 to 0.64, all P < 0.05). Diaphragm pressure-time product and thickening fraction correlated in 8 of 14 healthy subjects (ρ = 0.41 to 0.82, all P < 0.02) and in 2 of 25 mechanically ventilated patients (ρ = 0.63 to 0.66, all P < 0.01). Overall, diaphragm function as assessed with transdiaphragmatic pressure was weakly related to diaphragm thickening fraction. The diaphragm thickening fraction should not be used in healthy subjects or ventilated patients when changes in diaphragm function are evaluated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.