Abstract

This paper investigates the effects of aspect ratio and fibre fraction on the failure of engineered cementitious composite (ECC) concrete columns. When subjected to cyclic load, these columns may fail due to the strain-hardening of longitudinal bars or the formation of dominant cracks. In this experiment, 11 ECC columns with fibre fractions between 0–1.5 % and aspect ratios from 3–7, as well as a single reinforced concrete column, were tested. The results showed that both aspect ratio and fibre fraction significantly impacted the failure paths observed. Additionally, the ECC columns exhibited a cumulative energy dissipation capacity approximately 100 % higher than that of the conventional concrete column.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.