Abstract
In many cases, acetic acid is categorized as hazardous to health. A high-performance sensor for detecting acetic acid is urgently required. This study aims to observe the characteristics of quartz crystal microbalance (QCM) coated with polyacrylamide as an acetic acid sensor. For this purpose, we prepared the sensor by firstly coating with 1-dodecanethiol (using self-assembled-monolayers or SAM technique) followed subsequently by glutaraldehyde and polyacrylamide (PAM).As results, the sensors showed less sensitivity to humidity changes, which is one of the basic prerequisites for a stable sensor to an environment. We also obtained that the sensor showed relatively fast response time and high sensitivity to acetic acid vapor of about 96 seconds and 12.9 Hz/(mgL-1), respectively. Further research, however, is still required to improve the sensitivity and specificity by choosing more selective polymers.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.