Abstract

This study was done to evaluate the diagnostic accuracy of bedside chest radiography for pneumonia, adult respiratory distress syndrome (ARDS), or both in patients receiving mechanical ventilation. The series consisted of 40 patients; diagnostic accuracy was defined as the area under the receiver operating characteristic curve. Overall diagnostic accuracy for ARDS was 0.84. Overall diagnostic accuracy for pneumonia was 0.52. Review of previous radiographs and knowledge of clinical data did not enhance diagnostic accuracy for ARDS or pneumonia. Diagnostic accuracy for pneumonia was minimally reduced when ARDS was present. There was an increase in false-negative results because the diffuse areas of increased opacity in ARDS obscured the radiographic features of pneumonia. The authors conclude that chest radiography is of limited value for the diagnosis of pneumonia in patients receiving mechanical ventilation. The high false-negative and false-positive ratings for pneumonia resulted in a low diagnostic accuracy. The high diagnostic accuracy for ARDS was primarily due to the well-defined radiographic appearance of ARDS and few false-positive ratings.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.