Abstract

Abstract Natural gas is commonly utilized as the supply source for pneumatic control devices at small and medium sized tank batteries and for onshore wellhead separation, dehydration, and compression equipment. A pilot study to determine the quantity of methane emissions from these control devices was performed as part of the Natural Gas STAR Implementation Plan for Marathon Oil Company. It was quite comprehensive in that emissions from approximately 160 pneumatic control devices at 50 different production sites were measured. Control devices measured included pressure, level, and temperature controllers. The total losses from these high and low-bleed pneumatic control devices were small, with continuous-bleed level controllers emitting the largest quantity of methane. Retrofitting of these level controllers with low-bleed nozzles should be considered to reduce these losses. Based upon this pilot study, there is no economic justification to further quantify emissions from high and low-bleed pneumatic control devices in the study area because emissions that justify corrective action can be detected without measurement.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.