Abstract
Both asphalt concrete (AC) and Portland cement concrete (PCC) are limited in applications in tunnel pavements, due to special conditions in tunnel. To improve the fire resistance, durability and comfort of the tunnel pavements material, rubber particles, lightweight aggregate and polymer were added into PCC. Experimental results showed that physico-mechanical properties such as strength, rigidity, shrinkage and abrasion resistance got worse when rubber particles and lightweight aggregate were added, but when polymer was mixed, the physico-mechanical properties were enhanced dramatically. Microstructure analysis indicated that the interface transition zone (ITZ) influenced the physico-mechanical properties of concrete directly; the ITZ bondage between rubber particles or lightweight aggregate and cement matrix was very poor, which was the main reason for the decline of physico-mechanical properties; when polymer was mixed into the concrete, the ITZ structure were improved, which made the strain energy absorbing function of rubber particles can be exerted entirely, the flexibility and the strength of ITZ were boosted, thereby the physico-mechanical properties of concrete were improved.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.