Abstract
The current exposure standard of 0.02 ppm ceiling for MDI by definition refers to a gaseous species. The standard method, recommended by NIOSH, for measuring MDI in air, is also based on the the assumption that MDI is in the gas phase. Investigations in our Unit indicate that a major portion of airborne MDI, in working environments during spraying operations, is present as an aerosol. In view of this finding, the standard method would underestimate the MDI concentration and describing the airborne MDI concentration in "ppm" or "volume/volume unit" in invalid. A new method for calibration of the continuous reading monitors to measure airborne MDI concentration in mg/m3 unit is described.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.