Abstract
AbstractWe report polarized photon correlation measurements of bulk poly(phenylmethyl siloxane) (PPMS) with a molecular weight of about 2500 at different pressures from 1 to 1750 bar and temperatures between 269 and 308 K. In the Frequency range accessible by present‐day digital correlators, the time correlation function can measure a slow q2‐dependent diffusional process due to local concentration fluctuations and a fast α‐mode structural relaxation process. The mean characteristic times of the two processes approach each other at low temperatures and high pressures, in contrast to the behavior of the α‐ and β‐relaxation times. We should be cautious in relating the mean characteristic times for the structural relaxation process obtained by different experimental techniques, such as Brillouin scattering and photon correlation spectroscopy, because of the differnces in the probe emphasis and the extremely broad frequency distribution of such relaxation processes.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Polymer Science: Polymer Physics Edition
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.