Abstract

This study aimed to investigate the performance of a sequencing batch moving bed biofilm reactor (SB-MBBR) for biological P removal (Bio-P) treating diluted municipal wastewater at 10 °C and 20 °C, with volatile fatty acid (VFA) dosing during weekdays and without VFA dosing during weekends to simulate an industrial influenced wastewater. The overall results revealed that phosphorus removal efficiency for weekdays reached 53 % and 81 % at cold and moderated temperatures respectively. However, phosphorus removal efficiency for the weekend was 49 % for cold temperature and 52 % for moderate temperature. It was concluded that low temperature and low VFA might have suppressed the phosphate accumulating organisms (PAOs) performance. Besides, high extracellular polymeric substance (EPS) production might have hampered the PAOs activity, which could be linked to the observed high consumption of soluble chemical oxygen demand (SCOD) to P release ratio and thick biomass growth in the cold system.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.