Abstract
Application of conventional antenna phase measurement methods becomes increasingly difficult above 100 GHz. Main problems are the complexity of measurement set-ups and errors caused by the flexible cables or rotary joints needed in the system. To overcome these problems a novel differential phase measurement method has been developed. It was used to measure phase center positions and phase patterns of two corrugated horns at 105-115 GHz and 176-190 GHz. Good agreement between the measured values and theoretical values, calculated with the modal matching technique, was obtained.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.