Abstract
There is controversy over (1) the relative incidence of sore throat between the face mask (FM) and laryngeal mask airway (LMA), (2) the efficacy of LMA intracuff pressure reduction as a mechanism for minimizing sore throat, and (3) the relative incidence of sore throat with the LMA between males and females. In a randomized double-blind study, the authors compared laryngopharyngeal, neck, and jaw discomfort with the FM and LMA at high and low cuff volumes in males and females. Three hundred adult patients were randomly assigned to three equal-sized groups for airway management: (1) the FM, (2) the LMA with a fully inflated cuff (LMA-High), or (3) the LMA with a semi-inflated cuff (LMA-Low). Anesthesia was administered with propofol, nitrous oxide, oxygen, and isoflurane. In the FM group, a Guedel-type oropharyngeal airway and jaw thrust were used only if necessary. In the LMA groups, cuff inflation was achieved with either 15 or 30 ml for the size 4 (females) and 20 or 40 ml for the size 5 (males). The LMA was removed when the patient was awake. Patients were questioned 18-24 h postoperatively about surgical pain, sore throat, sore neck, sore jaw, dysphonia, and dysphagia, and about whether they were satisfied with their anesthetic. The incidence of sore throat was lower in the FM (8%) than the LMA-High (42%) and LMA-Low (20%) groups (both: P < or = 0.02). The incidence of sore neck was higher for the FM (14%) than the LMA-High group (6%; P = 0.05) but similar to the LMA-Low group (8%). The incidence of sore jaw was higher in the FM (11%) than the LMA-High (3%) and LMA-Low (3%) groups (both: P = 0. 02). There were no differences among groups for surgical pain or dysphonia. The incidence of dysphagia was lower in the FM (1%) than the LMA-High group (11%; P = 0.003), but similar to the LMA-Low group (1%). The incidence of sore throat and dysphagia was lower in the LMA-Low group than the LMA-High group for both males and females (all: P < or = 0.04). There were no differences in discomfort levels between males and females in any group. Two patients from the FM group and one from the LMA-High group were not satisfied with their anesthetic. These complaints were unrelated to postoperative morbidity. The LMA causes more sore throat and dysphagia but less jaw pain than the FM. Sore throat and dysphagia are more common with the LMA if the initial cuff volume is high. There are no differences in discomfort levels between males and females. However, these discomforts do not influence patient satisfaction after LMA or FM anesthesia.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.