Abstract

Permeability-glycoprotein (P-gp), an efflux transporter in several organs, acts at the blood-brain barrier to protect the brain from exogenous toxins. P-gp almost completely blocks brain entry of the PET radiotracer (11)C-N-desmethyl-loperamide ((11)C-dLop). We examined the ability of (11)C-dLop to quantify P-gp function in humans after increasing doses of tariquidar, an inhibitor of P-gp. Seventeen healthy volunteers had a total of 23 PET scans with (11)C-dLop at baseline and after increasing doses of tariquidar (2, 4, and 6 mg/kg intravenously). A subset of subjects received PET with (15)O-H(2)O to measure cerebral blood flow. Brain uptake of (11)C-dLop was quantified in 2 ways. Without blood data, uptake was measured as area under the time-activity curve in the brain from 10 to 30 min (AUC(10-30)). With arterial blood data, brain uptake was quantified with compartmental modeling to estimate the rates of entry into (K(1)) and efflux from (k(2)) the brain. Brain uptake of radioactivity was negligible at baseline and increased only slightly (approximately 30%) after 2 mg of tariquidar per kilogram. In contrast, 4 and 6 mg of tariquidar per kilogram increased brain uptake 2- and 4-fold, respectively. Greater brain uptake reflected greater brain entry (K(1)), because efflux (k(2)) and cerebral blood flow did not differ between tariquidar-treated and untreated subjects. In the subjects who received the highest dose of tariquidar (and had the highest brain uptake), regional values of K(1) correlated linearly with absolute cerebral blood flow, consistent with high single-pass extraction of (11)C-dLop. AUC(10-30) correlated linearly with K(1). P-gp function at the blood-brain barrier in humans can be quantified using PET and (11)C-dLop. A simple measure of brain uptake (AUC(10-30)) may be used as a surrogate of the fully quantified rate constant for brain entry (K(1)) and thereby avoid arterial sampling. However, to dissect the function of P-gp itself, both brain uptake and the influx rate constant must be corrected for radiotracer delivery (blood flow).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.