Abstract

This study investigates the efficacy and safety of personalized cyclophosphamide (CY) dosing in 50 patients receiving CY along with total body irradiation (TBI). Participants received CY 45 mg/kg with subsequent therapeutic drug monitoring using Bayesian parameter estimation to personalize the second CY dose to a target area under the curve (AUC) for carboxyethylphosphoramide mustard (CEPM) (a reporter molecule for CY-derived toxins) and for hydroxycyclophosphamide (to ensure engraftment). The mean second CY dose was 66 mg/kg; the total dose ranged from 45 to 145 mg/kg. After completion of this phase II study, we compared participants' clinical outcomes with those of concurrent controls (n = 100) who received TBI along with standard CY doses of 120 mg/kg. Patients receiving personalized CY dosing had significantly lower postconditioning peak total serum bilirubin (P = 0.03); a 38% reduction in the hazard of acute kidney injury (AKI) (P = 0.03); and nonrelapse and overall survival rates similar to those in the controls (P = 0.70 and 0.63, respectively) despite the lower doses of CY administered to most of the patients in the personalized dosage group.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.