Abstract

To compare stump pressure (SP), transcranial Doppler (TCD), electroencephalography (EEG) and selective shunting during carotid endarterectomy (CEA) with preoperative positron emission tomography (PET) parameters. Preoperative PET measurements and peroperative neuromonitoring were performed in ten patients undergoing CEA for symptomatic carotid artery disease. PET parameters measured were cerebral blood flow (CBF), oxygen extraction fraction (OEF), cerebral oxygen metabolism (CMRO(2)), cerebral blood volume (CBV), mean vascular transit time (MVTT) and cerebral perfusion pressure (CPP). Results of these measurements in ipsilateral medial cerebral artery (MCA), ipsilateral hemisphere and total cerebrum were compared with absolute mean SP, mean SP<40mmHg, TCD, EEG changes and selective shunting. None of the PET parameters showed any significant correlations with peroperative neuromonitoring findings. There were only trends for correlations of CBF and MVTT with TCD changes and of CPP and CMRO(2) with selective shunting. Preoperative PET examinations are not useful for predicting the need for shunting during CEA.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.