Abstract

To evaluate the perioperative, postoperative and functional outcomes of robot-assisted partial nephrectomy (RAPN) for renal tumours with high surgical complexity at a large volume centre. Perioperative and functional outcomes of RAPNs for renal tumours with a Preoperative Aspects and Dimensions Used for an Anatomical (PADUA) score of ≥10 performed at our institution between September 2006 and December 2012 were collected in a prospectively maintained database and analysed. Surgical complications were graded according to the Clavien-Dindo classification. Serum creatinine and estimated glomerular filtration rate (eGFR) were assessed at the third postoperative day and 3-6 months after RAPN. In all, 44 RAPNs for renal tumours with PADUA scores of ≥10 were included in the analysis; 23 tumours (52.3%) were cT1b. The median (interquartile range; range) operative time, estimated blood loss and warm ischaemia time (WIT) were 120 (94, 132; 60-230) min, 150 (80, 200; 25-1200) mL and 16 (13.8, 18; 5-35) min, respectively. Two intraoperative complications occurred (4.5%): one inferior vena caval injury and one bleed from the renal bed, which were both managed robotically. There were postoperative complications in 10 patients (22.7%), of whom four (9.1%) were high Clavien grade, including two bleeds that required percutaneous embolisation, one urinoma that resolved with ureteric stenting and one bowel occlusion managed with laparoscopic adhesiolysis. Two patients (4.5%) had positive surgical margins (PSMs) and were followed expectantly with no radiological recurrence at a mean follow-up of 23 months. The mean serum creatinine levels were significantly increased after surgery (121.1 vs 89.3 μmol/L; P = 0.001), but decreased over time, with no significant differences from the preoperative values at the 6-month follow-up (96.4 vs 89.3 μmol/L; P = 0.09). The same trend was seen for eGFR. In experienced hands RAPN for renal tumours with a PADUA score of ≥10 is feasible with short WIT, acceptable major complication rate and good long-term renal functional outcomes. A slightly higher risk of PSMs can be expected due to the high surgical complexity of these lesions. The robotic technology allows a safe expansion of the indications of minimally invasive PN to anatomically very challenging renal lesions in referral centres.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.