Abstract

A two-circuit cycle with parallel evaporators (called a “parallel cycle”) for a domestic refrigerator–freezer (RF) shows energy saving potential compared with a conventional cycle with a single loop or serial evaporators because of a low compression ratio in the fresh food compartment (R)-operation. The objective of this study is to investigate the effects of the refrigerant charge, R-capillary tube, and refrigerant recovery operation on the performance of a parallel cycle. In addition, design guidelines for the heat transfer area and air flow rate of an R-evaporator are proposed. When the parallel cycle was optimized in terms of the refrigerant charge and R-capillary tube diameter, the energy consumption was reduced by 7.8% over a bypass two-circuit cycle with the same RF platform. In addition, an additional energy saving of 1.8% was obtained by the optimization of the operating sequence and refrigerant recovery operation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.