Abstract

AbstractCurrent developments in the recently introduced method of HgI2 crystal platelet growth by polymer assisted vapor transport are described. Crystal parameters are evaluated by making electrical measurements on x-ray detectors fabricated from HgI2 platelets, Selection for detector fabrication is on the basis of size and apparent crystalline perfection. Detectors have been fabricated with active areas averaging 2 to 3 mm2 and thicknesses ranging from 20 to 400 µm. Values of electron mobility and mobility-lifetime product measured for HgI2 platelet material are among the highest ever observed for HgI2.The combination of low leakage current and good electron transport makes HgI2 platelets suitable for room-temperature x-ray spectrometry. An energy resolution of 370 eV (FWHM) for the 5.9 KeV Mn Kα line has been obtained, and representative low-energy x-ray fluorescence spectra are presented.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.