Abstract

A performance model for half-mask and single-use respirators is presented. It represents a possible alternative to field measurements of respirator performance. Experimental data on filter and leak performance given in Part I were used to develop a model that allows one to predict 1) the overall respirator penetration as a function of particle size for any work rate and 2) overall total mass penetration for any work rate and exposure aerosol-size distribution for a known respirator filter and facial seal leak condition. A simplified method based on general regression equations is presented that allows one to estimate these quantities based on QNFT (quantitative fit testing) measurements and a knowledge of the exposure aerosol-size distribution. Example calculations are given for a situation in which QNFT gives a fit factor of 50 for a half-mask with dust, fume and mist filter cartridges, but predicted protection factors for various use conditions range from 20 to 81 depending on exposure particle-size distribution and work rate of the wearer.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.