Abstract

The performance that can be achieved in a power plant obtained upgrading a typical aero-derivative gas turbine is analysed. The methodology is based on the off-design analysis of the gas generator (compressor and high pressure turbine) in the upgraded plant configuration and is applied to the design of a power plant based on the recuperative water injected cycle. The gas generator operating region and its boundary have been evaluated for the upgraded plant configuration; an optimization procedure has been established in order to show the maximum efficiency and power output that can be achieved.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.