Abstract
The performance that can be achieved in a power plant obtained upgrading a typical aero-derivative gas turbine is analysed. The methodology is based on the off-design analysis of the gas generator (compressor and high pressure turbine) in the upgraded plant configuration and is applied to the design of a power plant based on the recuperative water injected cycle. The gas generator operating region and its boundary have been evaluated for the upgraded plant configuration; an optimization procedure has been established in order to show the maximum efficiency and power output that can be achieved.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.