Abstract

In this paper, a bulb turbine, with unit specific speed of nq=223.1 min−1 suitable for low prototype head was studied from aspect of its performance. Hydraulic model of the turbine was developed firstly, and then model turbine was designed and manufactured. Performance tests were carried out on high-accuracy hydraulic machinery model universal test rig located at IWHR, including energy, cavitation and pressure fluctuation tests, etc. In order to investigate internal flow field, three-dimensional transient turbulence numerical simulation was conducted on the tested turbine, adopting Reynolds-averaged Navier-Stocks control equations and RNG k-ε turbulence model. Test and simulation results show that: (1) hydraulic efficiency of model turbine ηM is up to 91.7%, at the optimum operating point of n11o=165.54 r/min versus Q11o=1.93 m3/s; (2) numerical results agree well with experimental resultsby comparing pressure fluctuation, which shows that pressure amplitude is very low at the optimum operating point; (3) hydraulic loss in Outflow domain accounts for more than 50% total hydraulic loss due to flow separation and secondary flow.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.