This paper explains the research results of leakage current and flashover measurement on epoxy resin 20 kV outdoor insulators in a chamber at various artificial polluted conditions. The waveform of the leakage current (LC) was measured using a digital storage oscilloscope. The digital data was transferred to a personal computer using a RS-232 cable. Further analysis of the waveform was done using Fast Fourier Transform. The result showed that LC was affected by various environment conditions like pollution, humidity and temperature. The flashover of insulators occurred at 64 kV for 2600 muS and 53 kV for 4300 muS in clean fog and high humidity condition
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.