Abstract

This paper reports a performance analysis on CRGT power plants fuelled by DME, which is a potentially attractive fuel for gas turbines. The study also includes a performance comparison of simple cycle gas turbines fuelled by natural gas, DME and methanol. The study shows that, owing to the exhaust heat recovery carried out through DME pre-heating and vaporization before combustion, the efficiency of the DME fuelled turbine improves by about 1 point, without any significant change in power output. Thermochemical recuperation in DME fuelled turbines allows to achieve a significant performance improvement. For the highest water/DME molar ratio allowed by the minimum temperature difference here assumed, the power output of the CRGT plant is 44% higher than that of the reference plant, with a corresponding 54% efficiency (versus 41% of the reference unit) and a 8% decrease of the specific CO 2 emissions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.