Abstract

The efficiency assessment of a high-pressure turbine (HPT) stage is complicated by the presence of upstream and downstream purge flows. In fact, the efficiency calculation is often based on mass flow-averaged values of total temperature at the stage inlet and outlet planes. Moreover, the purge flow distribution in the annulus is usually unknown and therefore assumed to be uniform. This paper presents and applies an alternative method to calculate the efficiency of a fully purged HPT stage. Such a definition relies on seed gas concentration measurements at the HPT stage outlet plane to determine the outlet purge flow distribution. After comparing the alternative method to the standard definition (based on the assumption of uniform purge) for the nominal purge case, the efficiency variation between the case with nominal purge and the case without purge is investigated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.