Abstract

Water leakage monitoring system is essential for the urban water supply, but it is a great challenge to ensure stable and reliable power supply for this system. In this study, an inline cross-flow turbine was proposed to harvest hydropower from the water pipes. A numerical investigation was conducted to study the effects of blocks on the turbine performance. The simulation results indicated that the proposed upstream and downstream blocks can act as nozzle and diffuser in traditional cross-flow turbine to enhance the flow velocity and pressure difference through the impeller, so the turbine performance can be improved. The maximum output power of the turbine can research 136W when the TSR is 1.2 and the water head loss through the water turbine is in the range of 3.45m-3.75m water head, which has little negative impact on the normal water supply.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.