Abstract

This research evaluates the current DNA quantification (Quantifiler™ Trio, PowerQuant®, Investigator® Quantiplex® Pro and InnoQuant® HY Fast) and autosomal STRs amplification kits (GlobalFiler™, PowerPlex® Fusion 6 C, Investigator® 24Plex QS) using 62 degraded skeletal remains from armed conflicts (petrous bone, femur, tibia, and tooth) with several parameters (autosomal small, large, and male target, degradation index, probability of degradation, number of alleles above analytical threshold, number of alleles above stochastic threshold, RFU, peak height ratio, number of reportable loci). The best qPCR/autosomal STRs amplification tandem was determined by comparing quantification results by a DNA quantity estimation based on sample average RFU. InnoQuant® HY Fast was the most sensitive kit, and no significative differences were observed among amplification kits; however, Investigator® 24 Plex QS was found to be the most sensitive in our samples. That is why InnoQuant™ and Investigator® 24Plex QS were determined to be the best tandem.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.