Abstract

The BaBar detector is currently operating nearly 200 Resistive Plate Chambers (RPCs), constructed as part of an upgrade of the forward endcap muon detector in 2002. Although the average RPC efficiency remains high, numerous changes in the RPC performance (increased currents and rates) have been observed. A few of the highest rate RPCs have suffered efficiency losses of more than 15%. Several types of efficiency loss have been observed. Tests with humidified gas have shown that some of the lost efficiency is recoverable. However, efficiency losses in the highest rate regions have not yet improved with humid gases.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.