Abstract

The development of electric vehicles in Indonesia, especially the BEV (Battery Electric Vehicle) type, has received serious attention and support from the government. This is evidenced by the issuance of Presidential Regulation Number 55 of 2019 concerning the acceleration of the Battery-Based Electric Motor Vehicle Program for Road Transportation. Electric vehicles designed and developed in this study use an on-wheel BLDC type electric motor, Li-Ion batteries and are equipped with a watt hour meter to monitor battery consumption. The results of testing the accuracy and precision of the watt hour meter show a good value. This is evidenced by the difference in the measurement value of the watt hour meter against the Avometer and the difference between each repetition of the data 5 times which is below 1 Volt and 1 Ampere. Other test results show that the track with a large slope will also experience a large voltage drop, namely 0.8 V at a slope of 100 and the maximum current flowing is 8.35 A. Meanwhile, when the slope of the track is 70 and 60, the battery voltage decreases and the current flowing respectively are 0.5 V and 8.12 A; as well as 0.2 V and 7.84 A.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.