The purpose of this study was to measure the long-term moisture build-up in the walls of a house which had been retrofitted with Internal Wall Insulation. This was done by embedding moisture sensors in the walls and then monitoring values over an eight-year period. The results showed that the wall moisture of embedded wood piece sensors had increased to a value of 18–20 % over 8 years. In a comparable wall, which had been treated with water repellent brick cream, the build-up of moisture was significantly reduced to 9–10 % over the same period. This wall was examined after the 8-year period and no visible mould was evident.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.