Abstract
The functionality of poly(dimethylsiloxane) (PDMS)-based interferometric fiber sensors for volatile organic compounds (VOCs) detection is investigated and experimentally demonstrated. Two interferometric configurations are considered in this work, namely Fabry-Perot (FP) and Sagnac interferometers (SI). Both sensors are functionalized with a thin layer of VOC-sensitive polymer: PDMS, whose degree of swelling varies as a function of VOC concentrations. This swelling effect will result in an optical path length and birefringence modulation for FP and SI sensors, respectively. In this paper, the two common VOCs, ethanol and 2-propanol, were detected by the proposed sensor and the inverse matrix method was used to differentiate the VOC in gas mixture.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.