Abstract

In order to clarify PD mechanism and degradation of electrical tree in solid polymer insulator, PD patterns, pulse sequences and current shapes in an artificially simulated tree channel were investigated. A few hours after voltage application, new tree channels started to propagate. When they were propagating, the voltage increment between two consecutive PD pulses was constant in positive polarity in spite of PD magnitude changing. Furthermore, there were at least two types of PD current shapes in the same positive half cycle. This result suggests that there are different mechanisms of PD's in the same half cycle.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.