Abstract

Due to its great potential value in theory and application, nonlinear control strategies of doubly fed induction generator (DFIG), especially passivity-based control (PBC) methods, have been a focus in the literature. A PBC strategy for DFIG with time-varying load torque to track flux and speed trajectories is proposed in this paper. The key point of this method is the identification of terms, known as workless forces, which appear in the dynamic equations of DFIG but have no effect on the energy balance equation of the closed loop. The speed of DFIG is estimated via an ANN estimator avoiding the use of mechanical sensors. PBC combined with ANN speed estimator not only reserves the advantages of PBC such as nonexistence of singularity, but also rejects the flux and speed tracking error caused by stator and rotor resistance variation. This algorithm simplifies the control structure and enhances the robustness of the control system. The feasibility and effectiveness is testified by the experimental results based on dSPACE.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.