Abstract

The processes of passive sampling and electret collection are discussed. Two types of passive sampling chamber have been developed in our laboratory: a passive sampling chamber with electret collection (PSCE) used for environmental radon concentration monitoring and radon flux rate measurement; and a passive sampling chamber with and without electret collection (PSCP) used as a personal radon dosemeter and area radon monitor. The lower limits of detection for radon concentration monitoring are 3.0 T-1, 2.0*102 T-1 and 3.8*103 T-1 Bq m-3 for PSCE and PSCP with and without electret collection, respectively, where T is the sampling period in hours. The lower limit of detection for radon flux rate measurement with PSCE is 2.0*10-4 T-2 Bq m-2 s-1. The characteristics of the passive sampling monitoring techniques and some monitoring results are described.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.