Abstract

Although dead space is often increased in disease, it is not frequently measured in the clinic. This may reflect that an adequate method as well as reference values are missing. Healthy males and females, n=38, age 20-61 yrs, were connected to a pneumotachograph and a fast CO2 analyser after radial artery catheterization. The physiological dead space was partitioned into airway and alveolar dead space using a delineation principle denoted the pre-interface expirate. Physiological dead space was 201+/-41 mL in males and 150+/-34 mL in females. Dead space values were depending upon parameters reflecting lung size (predicted total lung capacity), breathing pattern and age. After multiple correlation the variation decreased and differences between males and females disappeared. The residual SD was then for physiological dead space 18.9 mL. The clinical use of the new method for determination of dead space can be based upon reference values, with a more narrow range than previous data.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.